Main Features:
1. This product has a good sensitivity which can measure the concentration of hydrogen within a wide range.
2. Long working life, low cost.
3. This product is able to work under simple driver circuit.
4. Family use gas leak alarm apparatus. .
5. Industrial combustible gas alarm apparatus.
Parameters |
Description |
Detectable concentration |
100-1000ppm(hydrogen) |
Circuit voltage( Vc) |
≤24V DC |
Heating voltage( VH) |
5.0V±0.2V AcorDC |
Load resistance( RL) |
adjustable |
Heating resistor( RH) |
31Ω±3Ω(indoor temperature) |
Heating power consumption( PH) |
≤900mW |
Surface resistance of Sensitive body( Rs) |
2KΩ-20KΩ(in 1000ppm H2) |
Sensitivity ( S) |
Rs(in air)/Rs(1000ppm hydorgen)≥5 |
Concentration slope(α) |
≤0.6(R5000ppm/R3000ppm CH4) |
Temperature |
20℃±2℃ |
Humidity |
65%±5%RH |
Standard test circuit |
Vc:5.0V±0.1V; VH: 5.0V±0.1V; |
Warm up time |
No less than 48hours |